The configuration summary chart is in the Main Panel (that is, the right panel). The chart reports how the ServeRAID Manager will configure your controller if you click Apply.
| Column | Information displayed |
| 1 |
The logical drive number. If this is a new logical drive, NEW is reported beside the number. |
| 2 |
The size (in MB) of the logical drive. |
| 3 |
The RAID level of the logical drive. |
| 4 |
The letter of the array in which the logical drive is contained. |
| 5 |
Whether the logical drive has a hot-spare drive available should a physical drive in the array fail (that is, become defunct). If a hot-spare drive of the appropriate size is available, this column reports Yes. If the logical drive is redundant (that is, RAID level-1, 1E, or 5), but a hot-spare drive of the appropriate size is not available, this column reports No (in red). If the logical drive is RAID level-0, this column reports No (in black). |